United States Stove Stove 6035 User Manual

Keeping  
North America Warm  
Since 1869  
CORN & PELLET MULTIFUEL STOVE  
6035  
OWNER’S MANUAL  
Installation - Operation - Maintenance Instructions - Repair Parts  
READ THIS ENTIRE MANUAL, THOROUGHLY, BEFORE ATTEMPTING TO INSTALL AND/OR  
BURN YOUR NEW AMERICAN HARVEST CORN AND PELLET MULTI-FUEL STOVE. FAILURE TO  
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURIES  
OR EVEN DEATH.  
Safety Notice: If this stove is not properly installed, a house fire may result.  
For your safety, follow the installation directions. Contact local building or fire officials  
about restrictions and installation requirements peculiar to your area. Do Not Plug  
this appliance into an electrical outlet before reading and understanding all operations  
and always unplug the unit before attempting any work or maintenance. Do not  
connect this stove to any chimney flue already serving another appliance. Carefully  
observe and maintain all clearances and combustibles.  
A note about fuel: Use only dried shelled corn with a moisture content of 14%  
or less (11 to 12% provides the best results); any pellet fuel used should have  
an ash content of 1% or less. If not efficiency will suffer, and your warranty may be  
voided.  
Your American Harvest Corn/Pellet Stove operates on a negative pressure. Therefore,  
all venting connections (elbows, T-pipe) must be sealed and airtight.  
Use Hi-Temp silicone at each joint or connection.  
SAVE THESE INSTRUCTIONS  
UNITED STATES STOVE COMPANY GRANTS NO WARRANTY, IMPLIED OR STATED,  
FOR THE INSTALLATION OR MAINTENANCE OF THE STOVE AND ASSUMES NO  
RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).  
UNITED STATES STOVE COMPANY - 227 INDUSTRIAL PARK ROAD-SOUTH PITTSBURG, TN. 37380  
TECHNICAL ASSISTANCE (423) 837-2100 - (423) 837-2109 FAX  
851576A
 
SAFETY STEPS  
IMPORTANT: Proper installation of this stove is necessary for safe and efficient operation.  
Installing this product improperly may result in a house fire and personal injury. All applicable  
building codes for your location must be followed. In areas where building codes require additional  
steps to the installation of this product not included in this manual the building codes will take  
precedent and must be followed. Contact your local building inspector to obtain any necessary  
permits or inspection guidelines before installing the product.  
• The American Harvest stove is designed to burn shelled corn, cherry pits, or pelletized fuel such as  
wood pellets. The burning of other solid fuels such as cord wood or wood chips in this stove is not  
permitted.  
• This product requires simple periodic maintenance for proper operation and long life of the stove. Read  
and follow the maintenance schedule closely.  
DISCONNECT THE POWER CORD BEFORE SERVICING THIS STOVE! A power surge protec-  
tor is required. The unit must be plugged in to a grounded 110-volt power source.  
• Always route the power cord away from the unit. Do not route cord in foot traffic areas. Do not pinch  
cord under furniture.  
• A working smoke detector must be installed in the same room as this product.  
• Flammable or explosive liquids such as gasoline, naphtha or engine oil must NEVER be used in or around  
this stove. These liquids must be stored well away from this stove as the open flame in the burner  
chamber could ignite the fumes of such liquids. Do not burn garbage in this unit.  
• The moving parts of this stove are propelled by high torque electric motors. The auger and Fuel Agitator  
can cause severe injury to body parts that may get near them. Keep all body parts away from the  
auger and Fuel Agitator while the stove is plugged into an electrical outlet. These moving parts may  
begin to move at any time while the stove is plugged in.  
• According to HUD requirements, when installed in a mobile home, this stove must be grounded directly to  
the steel chassis of the mobile home and bolted to the floor. Direct air access must be provided - Use  
60FAK Fresh Air Kit  
• This stove is not intended for use in commercial installations.  
• Do not connect this stove to “B” vent. Use UL Listed Pell Vent ONLY!  
BURNING SOLID FUELS  
Ashes will have to be Removed from the stove periodically. See cleaning procedure. You can minimize cleaning required  
and maximize efficiency by maintaining the correct draft settings. See “Draft Setting” further in the manual.  
The draft setting on your stove may have to be changed from time to time to accommodate your specific burning conditions.  
Proper draft setting will be discussed later in this manual. The point we wish to make here is that your American Harvest  
stove, due to the nature of solid fuels, will require brief periodic attention. Please do not expect to light your stove and walk  
away from it until you want to shut if off in the spring. A few moments of adjustment and cleaning from time to time is an  
important part of burning solid fuels, due to the vast differences in fuel, humidity and outside temperature.  
The American Harvest stove has been designed to burn dry shelled corn, wood pellets and other pelletized fuels that meet  
Association of Pellet Fuel Industries standards.  
USSC  
3
 
BURNING SOLID FUELS continued...  
SHELLED CORN (Dry, preferably corn with 11- 12% moisture content)  
Corn must contain less than 14% moisture content. Wet corn will rapidly deteriorate stove components, reduce  
efficiency and void all warranties. Purchase a moisture tester if in doubt.  
Corn must be clean and free from debris. Never burn corn right from the field. Damage caused by dirty corn is not  
covered by the product warranty. Ask for clean filtered bagged corn only. Stalk parts, excessive fines and cob remmants  
will clog the auger.  
NEVER BURN SEED CORN IN YOUR STOVE. Seed corn is treated with chemical pesticides that are harmful or fatal if  
swallowed, therefore, seed corn is dangerous to have in the house, especially where children can reach it.  
Never burn “Deer Corn.” It frequently contains molasses/sugars.  
Store your corn supply in a dry place and keep bags or container sealed to prevent your corn from absorbing excess  
moisture. Test the moisture content periodically to maintain the proper dryness.  
There are many varieties of corn grown around the world. Each variety has unique characteristics including the shape  
and size of the kernel. Your stove will burn more consistently with a small to midsize kernel corn. If the kernel size of  
the corn varies greatly or if you switch sources frequently, you will get a less consistent burn, which will require more  
attention to the draft setting on your stove. Therefore, purchasing corn from the same source will help achieve a more  
consistent burn. DO NOT USE CORN WITH A HIGH WAX CONTENT!  
WOOD PELLETS  
As with corn, be consistent in your pellet supplier. Pellets will vary in content and burn characteristics from supplier to  
supplier. A consistent supply of pellets will require fewer adjustments to the draft of the stove.  
Check your pellets for foreign objects. Your stove warranty will not cover damage done to your stove due to foreign  
objects in the fuel supply.  
Store your pellets in a dry place to prevent them from absorbing excess moisture.  
To decrease sawdust buildup, the hopper will need to be vacuumed out after every 6-8 bags of pellets or more often if  
the pellets are poor quality. You may have to screen each bag of pellets if sawdust becomes a problem.  
Wood Pellets vary in size and ash content from less than 1% to 3% or more. Your stove will burn more efficiently with  
small to midsize pellets. Low ash content pellets will allow you to burn the stove longer between cleanings. Only wood  
pellets manufactured to the Association of Pellet Fuel Industries (A.P.F.I.) standard for residential pellets fuels are  
recommended. Performance will suffer if nonstandard pellets are used. Consult your local American Harvest reseller  
for more information on approved wood pellet fuel.  
CAUTION: DO NOT PLACE SUCH FUELS WITHIN THE SPACE HEATER’S INSTALLA-  
TION CLEARANCES OR WITHIN THE SPACE REQUIRED FOR CHARGING AND ASH  
REMOVAL.  
4
USSC  
 
INSTALLATION REQUIREMENTS  
FLOOR PROTECTION  
The American Harvest Multifuel Stove may be installed on a combustible floor, with proper floor protection, or on a  
masonry hearth. The hearth or noncombustible floor protector must extend a minimum of (6) inches (152mm)in front  
and (6) inches (152mm) from each side of the ash removal door.  
CLEARANCES TO COMBUSTIBLES  
The stove must be installed with the following minimum clearances to side and back wall combustible materials. NOTE:  
These are minimum clearances to combustible walls established by the testing lab. The amount of room needed on the left  
side of the unit to access the electrical panel is (6) six inches (152mm).  
PARALLEL - A - Left Sidewall to Top Edge of Unit  
B - Sidewall to Flue  
C - Backwall to Flue  
D - Backwall to Unit  
E - Right Sidewall to Top Edge of Unit  
CORNER - F - Adjacent Wall to Flue  
G - Adjacent Wall to Unit  
6 in./152mm  
5 in./127mm  
3 in./75mm  
9 in./228mm  
2 in./50mm  
3 in./75mm  
4 in./100mm  
BACK WALL  
BACK WALL  
Alcove / Backwall / Sidewall  
Parallel / Alcove Installation  
Corner Installation  
USSC  
5
 
CLEARANCES TO COMBUSTIBLES continued...  
The side and top clearance are to be used when  
installing in an Alcove as shown to the left and  
below.  
6”  
min.  
HEARTH PROTECTION  
6”  
min.  
6”  
min.  
These clearances must be maintained and may only be reduced by means approved by the regulatory authority  
GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN  
It is recommended that only an authorized installer install your pellet/corn stove. The following installation  
guidelines must be followed to ensure conformity with both the safety listing of this stove and to local building codes.  
INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.  
A listed 3” or 4” type “PL” pellet vent exhaust system must be used for FREESTANDING installation and attached to the  
pipe connector provided on the back of the stove. Use a 3” to 4” adapter for 4” pipe. A cap must be used at the  
termination of type “L” vent chimneys.  
Do not terminate vent in any enclosed or semi-enclosed area, such as; carports, garage, attic, crawl space, under a  
sundeck or porch, narrow walkway or close area, or any location that can build up a concentration of fumes such as a  
stairwell, covered breezeway etc.  
Vent surfaces can get hot enough to cause burns if touched by children. Noncombustible shielding or guards may be  
required. Do not install a flue damper in the exhaust vent of this unit.  
Termination must exhaust above air inlet elevation. It is recommended that at least 5 ft. of vertical pipe be installed  
when the appliance is vented directly through a wall. This will create some natural draft to prevent the possibility of  
smoke or odor during appliance shutdown and to keep exhaust from causing a nuisance or hazard from exposing  
people or shrubs to high temperatures. In any case, the safest and preferred venting method is to extend the vent  
through the roof. Do not connect this unit to a chimney flue serving another appliance.  
Distance from doors and windows, gravity or ventilation air inlet into building:  
Not less than 4 ft./1.2m below, 4ft./1.2m horizontally from, 1ft./305mm above(This does not apply if the  
windows are non-opening or have been fixed so they cannot open.)  
6
USSC  
 
GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN continued...  
Distance from bottom of termination and grade-1ft./305mm minimum. This is conditional upon the plants and nature of  
grade surface. The exhaust gases are not hot enough to ignite grass, plants or shrubs located in the vicinity of the  
termination. The grade surface must not be a lawn. Distance from bottom of termination and public walkway is 7ft./  
2.1m minimum.  
Distance to combustible materials-2ft./610mm. This includes adjacent building, fences, protruding parts of the struc-  
ture, roof overhang, plants and shrubs, etc.  
°
It is recommended that a single or double clean-out “tee” be installed at every 90 junction to enable collection of fly ash  
°
and to permit periodic cleaning of the exhaust system. 90 elbows accumulate fly ash and soot thereby reducing  
exhaust flow and performance of the stove. Each elbow or tee reduces draft potential by 30% to 50%.  
Total length of horizontal vent must not exceed 48”(4ft.)/1,200mm. All joints in the vent system must be fastened by at  
least 3 screws, and all joints must be sealed with RTV silicone sealer to be airtight.  
When venting into an existing masonry or factory built chimney, the chimney must be cleaned, with all creosote re-  
moved. The chimney must be a type suited for solid fuel. WARNING: The chimney and the chimney connections must  
be kept clean an in good condition. Such intallations are not recommended, unless a vent pipe extends beyond flue exit.  
The “PL” vent or single wall stainless exhaust system must be installed so as to be GAS TIGHT! The vent manufacturer’s  
installation procedures must be followed. In addition, pipe connections, joints and all pipe seams within the home  
should be sealed with high temperature RTV silicone sealer.  
The area where the chimney penetrates to the exterior of the home must be sealed with silicone or other means to  
maintain the vapor barrier between the exterior and the interior of the home.  
Where installations will be made in locations above 2,000 feet, it is recommended that your stove be installed with 4” pell  
vent. At elevations above 3,000 feet, it is mandatory that a 4” pell vent be used for your installation.  
NOTE: These are guidelines only. Proper venting is accomplished by design and common sense. In most  
installations 3” inch diameter venting is adequate. If it does not vent properly you will have to change it  
to 4”.  
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM  
USSC  
7
 
DESIGN GUIDELINES FOR OUTSIDE COMBUSTION AIR CONNECTION  
1) For installations with horizontal through-the-wall exhaust, it is strongly recommended that the stove combustion air be  
connected to the outside. If the home is newer or has been tightly insulated it is required to install outside combustion  
air. If you do not, then bring a 4-6 inch intake into the furnace room in the basement.  
2) Connection to outside the house is REQUIRED for mobile home installations. We strongly urge use of the 60FAK Fresh  
Air Kit.  
90 DEGREE BEND TERMINATION  
WIND HOOD TERMINATION  
Wind Hood  
3” Min. Diameter  
3”  
NOTE:  
A wire mesh screen with a  
maximum opening size of 3/8”  
must be installed.  
6”  
2”  
3) Only noncombustible pipe 2 inches in diameter is approved to use for outside air connections (straight or flexible). PVC  
pipe is NOT approved and should NEVER be used.  
4) If the air inlet is connected to the outside, it MUST be terminated with a vertical 90-degree bend (down) or with a wind  
hood. Failure to do so could result in a burn back during high winds blowing directly up the air inlet during a simulta-  
neous power failure (see diagram above).  
5) Blockage, excessive length, or bends in the air intake pipe will starve the stove of combustion air. A 90-degree bend is  
equivalent in restriction to approximately 30 inches of straight inlet pipe.  
CAUTION: The operation of exhaust fans such as bath room fans, attic fans, etc. might starve the heater of combustible air  
creating a negative pressure in the room. Provide adequate ventilation in the room accompanying the heater. If not, the  
pressure switch may shut off operation of the heater. (Due to negative pressure)  
8
USSC